Selection Guide for Explosion-proof Weighbridges in Zone 1/2 Gas Atmospheres & Zone 21/22 Dust Atmospheres

When selecting explosion-proof weighbridges for hazardous explosive environments, it is essential to confirm the specific type of on-site explosive atmosphere, explosion-proof grade, explosion-proof type, temperature class, and other core parameters.

Explosion Proof Small Weighbridge6

Division of Explosion-proof Zones

Gas hazardous areas are classified into Zone 0, Zone 1, and Zone 2; dust hazardous areas are classified into Zone 20, Zone 21, and Zone 22. Explosion-proof electrical equipment for different atmospheres cannot be mixed for use. Gas-explosion-proof devices are not applicable directly in dust-hazardous areas. For special sites with coexisting flammable gas and combustible dust, products with dual-environment explosion-proof certification are mandatory.

Hazard Classification Grade

The higher the hazard level of the area, the stricter the requirements for explosion-proof equipment. Zone 0 has the most stringent requirements, followed by Zone 1 and Zone 2 in sequence. Equipment certified for Zone 0 can be used in Zone 1; equipment certified for Zone 1 applies to Zone 2.

  • Gas atmosphere explosion-proof grades: Ga, Gb, Gc (Priority: Ga>Gb>Gc)
  • Dust atmosphere explosion-proof grades: Da, Db, Dc (Priority: Da>Db>Dc)

Applicable Explosion-proof Types

Gas AtmosphereDust Atmosphere
Zone 0: Only Ex ia, ma type.
Zone 1: Ex d, ib, e, p type.
Zone 2: Ex ic, n type, and all higher-level explosion-proof types
Zone 20: Only Ex tD Da type; Db/Dc are prohibited.
Zone 21: Ex tD Db type.
Zone 22: Both Ex tD Db and Dc types are acceptable

Characteristics of Explosive Substances

  • Medium classification: Class II gas / Class III dust
  • Gas group ranking: ⅡA<ⅡB<ⅡC (ⅡC is the strictest standard, suitable for hydrogen, acetylene, and other extreme hazardous gases)
  • Dust category: Conductive dust, combustible dust, fibrous dust

Temperature class: T1 ~ T6 (T6 is the optimal grade)

T1=450℃, T2=300℃, T3=200℃, T4=135℃, T5=100℃, T6=85℃

Lower surface ignition temperature means higher safety performance.

Ingress Protection Grade: IP grade ≥ IP65 for dust environments and outdoor application scenarios.

All explosion-proof electrical appliances used in hazardous areas must be fully matched in explosion-proof grade, explosion-proof type, temperature class, and sealing grade.

Hazardous ZoneExplosion-proof TypeDc Grade Medium and Temperature ClassExplosion-proof GradeTypical Explosion-proof Mark
Gas Zone 0Ex ia, ma, sClass ⅡA/ⅡB/ⅡC (ⅡC is the strictest)T1~T6(T6 features the lowest surface temperature and highest safety level)High (Ga)Ex iaⅡC T6 Ga
Gas Zone 1Ex d, ib, e, pMedium (Gb)Ex dbⅡC T6 Gb
Gas Zone 2Ex ic, n & full seriesLow (Gc)Ex icⅡC T6 Gc
Dust Zone 20Ex tDClass ⅢA/ⅢB/ⅢCIngress Protection Grade:≥IP65 for dust hazardous areas≥IP65 for outdoor installationHigh (Da)Ex iaⅢC T200 130℃ DaEx tD Da IP65 T130℃ⅢC
Dust Zone 21Ex tDMedium (Db)Ex tD ⅢC T80℃ Db(200A)
Dust Zone 22Ex tDLow (Dc)Ex tD Dc

Core Configuration of Explosion-proof Weighbridge

When the weighbridge body is installed in hazardous areas, three key components are required: an intrinsic safety explosion-proof load cell, an intrinsic safety explosion-proof junction box, and flame-retardant signal cable.

If the weighing indicator is placed in hazardous areas, a flameproof enclosure type weighing indicator or flameproof weighing controller shall be adopted. Safety barriers must be equipped at sensor interfaces inside the flameproof box.

1. Intrinsic Safety Explosion-proof Load Cell

Dual gas & dust explosion-proof sensors with Ex ia grade are recommended.

Typical marks: Ex iaⅡC T4 Ga, Ex iaⅢC T200 130℃ Da (applicable for all gas Zone 0/1/2 and dust hazardous areas)

Technical Parameters:

  • Accuracy: 0.02%, OIML C3 grade
  • Allowable overload: 125%; Ultimate overload: 150%
  • Ingress Protection: IP68

2. Intrinsic Safety Explosion-proof Junction Box

Adopt dual gas & dust explosion-proof accessories of Ex ia grade.

Typical marks: Ex ia IIC T6 Ga, Ex iaⅢC T200 80℃ Da

Applicable for installation in Zone 0,1,2 hazardous areas.

3. Flameproof Enclosure Weighing Indicator / Controller

The enclosure is made of cast aluminum with a plastic-sprayed surface or a welded, sealed metal structure with surface spraying. It is fitted with a tempered glass display window and explosion-proof operation buttons on the front panel. Special certified safety barriers are installed at sensor ports inside the box to convert non-intrinsic safety interfaces into intrinsic safety ones. Flameproof cable glands are equipped at the bottom for connecting the power supply and flame-retardant signal cables.

  1. Ingress Protection Grade: IP66
  2. Common explosion-proof grades:
  • Ex dbⅡB T6 Gb, Ex dbⅡC T6 Gb, Ex tb ⅢC T80℃ Db(200A)
  • Ex dbⅡB T4 Gb, Ex dbⅡC T4 Gb, Ex tb ⅢC T130℃ Db(630A)

Application Scope

The explosion-proof weighbridge body can be deployed in Gas Zone 0/1/2 and Dust Zone 20/21/22.

Flameproof box-type weighing indicators are suitable for Gas Zone 1/2 and Dust Zone 21/22.

BINCEN explosion-proof weighbridges are fully applicable for overall installation in Gas Zone 1, Zone 2 as well as Dust Zone 21, Zone 22.