Explosion Proof Truck Scale

Our explosion-proof weighbridge is purpose-built for LPG stations, chemical plants, oil depots, hazardous waste facilities and other explosive hazardous areas. It operates safely in Zone 0/1/2 classified locations for vehicle weighing, trade settlement, inventory control and site safety management.

To meet varying global explosion protection standards, we adopt a modular compliance design: standard weighbridge structure with certified electrical components configurable per regional requirements. This avoids repeated development and ensures fast compliance worldwide.

Ⅰ. Product Overview

Our explosion-proof weighbridge is purpose-built for LPG stations, chemical plants, oil depots, hazardous waste facilities and other explosive hazardous areas. It operates safely in Zone 0/1/2 classified locations for vehicle weighing, trade settlement, inventory control and site safety management.

To meet varying global explosion protection standards, we adopt a modular compliance design: standard weighbridge structure with certified electrical components configurable per regional requirements. This avoids repeated development and ensures fast compliance worldwide.

图片1 5
Main Product (Standard Configuration)Scale Body:Modular steel construction with full anti-corrosion treatment, high strength, impact resistance and long service life.Explosion-proof Rating: Ex ia IIC T4 (Intrinsically Safe, suitable for Zone 1 hazardous areas)
Core Components:Sensors, instruments, weighing display controllers, junction boxes, and explosion-proof control cabinets are all selected from leading domestic brands, with valid national explosion-proof certificates (NEPSI / CNEx).1) Explosion-proof Weighing Sensor: Ex ia Ⅱ C T4 Ga; Ex ia ⅢC T200 130 130℃ Da2) Explosion-proof Junction Box: Ex ia IIC T6 Ga, Ex ia ⅢC T200 80℃ Da3) Flameproof Explosion-proof Distribution Cabinet / Weighing Instrument (Weighing Controller):Ex db Ⅱ B T6 Gb; Ex db Ⅱ C T6 Gb; Ex tb ⅢC T80℃ Db(200A);Ex db Ⅱ B T4 Gb; Ex db Ⅱ C T4 Gb; Ex tb ⅢC T130℃ Db(630A);
Optional Configuration (For Export Requirements)According to the regulations of your country or region, we can configure sensors, instruments, and junction boxes that meet local certification requirements, with corresponding additional charges applicable.

II. Certification Compliance Statement

ComponentCertification BodyExplosion-proof MarkRemarks
Load CellNEPSIEx ia IIC T4 GaValid in China
IndicatorCNExEx db [iaGa] IIB T6 GbValid in China
Junction BoxCNExEx ia IIC T6Valid in China
MetrologyCPAn=6000Keli, Yaohua or other Chinese brand indicators
265
3E7E7328A7FAF5672380FA312CB75E6E

Optional Certification Kits (Export Compliance)

Target MarketCertification RequirementOffered Component PackageAdditional Cost
European UnionATEX 2014/34/EUATEX-certified load cell + ATEX-certified indicator + matching junction boxQuoted by configuration
International GeneralIECExIECEx-certified load cell + IECEx-certified indicator + matching junction boxQuoted by configuration
North AmericaFM / ULFM/UL-certified load cell + indicator (customization required)Quoted by configuration
China (Trade Settlement)CPACPA-certified indicator (Keli D39-WB)Quoted by configuration

Why Choose Our Solution?

  • No need to stock inventory for different markets:We configure certification kits based on your specific requirements, helping you reduce inventory costs.
  • All optional components hold valid explosion-proof certificates:Traceable and fully compliant for customs clearance.
  • Compatibility declaration provided:Ensures the full system compliance of the combined load cell + indicator + junction box.
  • Support for third-party inspection & customs documentation assistance

III. Certification Kit Description

Standard Optional Configuration (Recommended)

The following configurations are based on our pre-validated component combinations, which can be directly used for export to the EU or IECEx member states:

ComponentATEX Kit (EU)Remarks
Load CellKeli FB-XZ (SCA24ATEX292X)New 2024 certificate, Ex ia IIC T4 Gb
IndicatorUtilcell SMART ATEX or Radwag PUE HX5.EX-2Intrinsically safe parameters precisely matched to the load cell
Junction BoxMatching explosion-proof junction box (Ex ia)Compatible with load cell / indicator
DeliverablesFull set of ATEX certificates + Compatibility DeclarationCustoms-clearable and traceable
2 1 2

Other Certification Kits

Certification TypeAvailabilityRemarks
IECExConfigurable on demandCan be configured with customer-specified brands
FM/ULCustom projectRequires additional lead time (8-12 weeks)
CPA (China Metrology)In stockKeli , Yaohua

IV. Important Notes

1. Pricing of Certification Kits

Certification kits incur additional charges for the following reasons:

  • Different countries have varying certification standards (ATEX, IECEx, FM/UL, etc.), making it impractical to maintain stock for all markets.
  • We will source certified components specifically to meet the requirements of your region based on your order.
  • Compatibility testing and documentation preparation are required (including certificate translation, notarization, etc.).

2. Quotation Process

Please indicate your target country when making an inquiry, and we will provide a customized quotation including the required certification kit.

3. System Compatibility

Intrinsically safe system components must be strictly matched by their parameters. We will:

  • Calculate the intrinsic safety parameter matching between the load cell and indicator based on your certification requirements.
  • Provide a written compatibility confirmation letter.
  • Arrange for a matching report from a third-party testing authority if required (at an additional cost).

V.Information Required When Making an Inquiry

To provide you with an accurate customized quotation, please include the following information in your inquiry:

  • Target country/region
  • Do you require explosion-proof certification? (If yes, please select: ATEX / IECEx / FM/UL / Other)
  • Do you require trade metrology certification? (If yes, please select: CPA China / OIML International / Other)
  • Estimated annual volume
  • Other requirements (e.g., explosion-proof large display, printer, barrier gate, unattended weighing system, etc.)

FAQ

A: The scale structure itself does not require explosion-proof certification (no electrical components). Core electrical parts (load cells, indicators, junction boxes) can be configured with ATEX/IECEx-certified products upon request. Currently, we can supply certified Keli load cells (ATEX SCA24ATEX292X) and ATEX indicators from brands like Utilcell/Radwag.

A: Yes. We will source third-party ATEX-certified indicators and load cells as a matched set, and provide a system compatibility declaration to ensure the combined assembly remains compliant with ATEX requirements. Additional costs and lead time for the certification kit will be clearly stated in the quotation.

A: Since certification standards vary by country, it is impractical to stock components for all markets. We source certified parts specifically to meet your regional requirements based on your order, and conduct compatibility testing and document preparation. These additional costs mainly cover:

Procurement of third-party certified components

Compatibility testing and document preparation

Certificate translation/notarization (if required)

A: Yes, but the FM/UL system is not compatible with ATEX/IECEx, requiring separate quotation and a longer lead time (approx. 8-12 weeks). This is recommended for customers with larger annual volumes, for whom we can develop a dedicated FM/UL certification kit.

A: Based on your target certification requirements, we will calculate the intrinsic safety parameter matching between the load cell and indicator, and provide a written compatibility confirmation letter. If required, we can also arrange a matching report from a third-party testing authority (at an additional cost).

A: Yes, but intrinsically safe system components must be strictly matched by their parameters. We can provide certified load cells and indicators separately with their respective intrinsic safety parameter sheets. However, the final compliance responsibility for the complete system rests with you. An additional document preparation fee applies if you require a compatibility declaration from us.

| related products

Explosion-Proof Small Weighbridge

Bincen’s explosion proof small weighbridge offers a robust and reliable weighing solution specifically designed for hazardous environments.

Explosion Proof Control Cabinet

Bincen explosion proof control cabinets are designed for hazardous environments. The cabinet features a durable aluminum alloy casing, explosion-proof construction,…